400A AC/DC Dual-Display Auto-Ranging Digital Clamp Meter
CL490
- Dual Display digital clamp meter allows users to see readings in tight space areas
- AC/DC clamp meter with True RMS provides accurate and reliable measurements across various applications
- Measures AC/DC current and NCVT via clamp; AC/DC voltage, resistance, continuity, frequency/duty cycle, DC microamps, diode test and capacitance via test leads; temperature via thermocouple
- Backlit reverse-contrast LCDs for clear data and best view-ability in all environments
- Withstands drops from 6.6 feet (2 m), and includes right-angle input test leads, thermocouple, storage pouch, instruction manual, and 2 x AA batteries
- Ergonomic design provides a comfortable grip, with easy dial adjustment using the thumb
- Non-contact voltage detection is integrated into the clamp jaw, with audible and visual indicators that intensify as the clamp moves closer to the voltage source
- Clamp body includes a side-mounted test lead holder and a back mount that accommodates an optional magnetic hanger (Cat. Nos. 69445 or 69417) for hands-free operation
Klein Tools CL490 Dual Display Clamp Meter is auto-ranging for precise measurements with a secondary display for easier viewing in tight spaces. The meter reads AC/DC current, voltage, resistance, continuity,frequency, and capacitance; all with True RMS accuracy. It features diode testing and temperature is taken, via thermocouple. There is NCV detection with audio-visual alerts for additional functional applications. To ensure visibility in any lighting, there is a backlit and hi-vis display.
Specifications
Type:
          Dual Screen AC/DC Current TRMS Clamp
        Application:
          Measures AC/DC Current and NCVT via the Clamp and AC/DC voltage, DC Microamp Current, Resistance, Continuity, Frequency, Duty-Cycle, Capacitance and Tests Diodes via the Test Leads, and Temperature with Thermocouple
        Special Features:
          Bottom Display; Automatically Ranging; TRMS Measurement; AC/DC Current Measurement; High Visibility Reverse Contrast LCD; NCVT
        Material:
          ABS/Electronics
        Batteries:
          2 x AA
        Auto-Power Off:
          Yes, Unless Disabled on Startup
        Jaw Size:
          1.6'' (4.1 cm)
        Drop Protection:
          6.6' (2 m)
        Display:
          4000 Count  Backlit, Hi-Viz
        Display Size:
          Main Display: 1.54'' x 0.86'' (3.9 cm x 2.2 cm) Secondary: 1.04'' x 0.72'' (2.6 cm x 1.8 cm)
        Functions:
          TRMS, AC/DC Current, NCVT, AC/DC Voltage, Resistance, DC microamp, Frequency, Capacitance, Continuity, Duty Cycle, Diode Test, and Temperature
        Auto Ranging:
          Yes
        TRMS:
          Yes
        Voltage:
          600V AC/DC
        Frequency:
          10Hz - 60kHz
        Current:
          400A AC/DC
        Capacitance:
          4000µF
        Ohms (Resistance):
          40MΩ
        AC Voltage:
          600V
        DC Voltage:
          600V
        DC Polarity Indicator:
          Yes
        DC Micro-Amp:
          200µA
        Temperature Range:
          -40° to 1832°F (-40° to 1000°C)
        Accuracy:
          ± (% of Reading + # of Least Significant Digits) Refer to Manual for Accuracy Depending on Active Function Selection Values Stated at 65° to 83°F (18° to 28°C)
        Standard:
          CATIII 600V, Class 2, Double Insulation Safety Rating IEC EN 61010-1, 61010-2-032. IEC EN 61326-1, 61326-2-2.Conforms to UL STD.61010-1, 61010-2-032;Certified to CSA STD.C22.2 NO. 61010-1, 61010-2-032
        Included:
          Clamp Meter; Carrying Case; Instructions; Test Leads; Thermocouple; 2 x AA Batteries
        Overall Length:
          3.54'' (9 cm)
        Overall Height:
          8.46'' (21.5 cm)
        Overall Width:
          1.5'' (3.8 cm)
        Weight:
          12.20 oz (346 g) Including Batteries
        UPC:
          092644694271
        Warnings
- Read, understand and follow all instructions, cautions and warnings attached to and /or packed with all test and measurement devices before each use.
- Do not attempt to measure resistance or continuity on live circuits.
- Before each use verify meter operation by measuring a known voltage or current.
- Do not use the meter during electrical storms or in wet weather, and do not use the meter or test leads if they appear to be damaged.
- Usage of this meter in any way other than that specified by the manufacturer can impair safe operation, resulting in severe injury or death.